Rinnai FS35ETRBN/US Manuale Utente

Navigare online o scaricare Manuale Utente per Camini Rinnai FS35ETRBN/US. Rinnai FS35ETRBN/US User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
FS35ETRBN/US FS35ETRSN/US
FS35ETRBL/US FS35ETRSL/US
Gas Radiant Space Heater
Owners Operation and Installation Manual
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT T O DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified
inst aller , service agency or the gas supplier .
This heater has been designed to code ANSI Z 21.88a-2000
effective 7-1-2002
This appliance is only for use with the type of gas indicated on
the rating plate.
This appliance is not convertible for use with other gases.
INSTALLER: MUST LEAVE THIS MANUAL WITH THE UNIT AFTER INSTALLATION
OWNER: RETAIN THIS MANUAL SAFELY, FOR FUTURE REFERENCE
zx
HOME OWNER / INSTALLER
FOR YOUR SAFETY
THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
WARNING: If the information in these instructions are not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - Gas Radiant Space Heater

FS35ETRBN/US FS35ETRSN/USFS35ETRBL/US FS35ETRSL/USGas Radiant Space HeaterOwners Operation and Installation ManualDo not store or use gasoline or o

Pagina 2 - RINNAI FIREPLACE HEATER

10deactivate the LOCK press and hold thebutton for 3 seconds until the indicatorgoes off.During normal operation the LOCK may beactivated and all con

Pagina 3 - CONTACTS

11proceed to TIMER 2 - which isprogrammed in the same way - or threetimes to return to the clock display. Thismust be done within 1 minute of setting

Pagina 4 - DIMENSIONS

12NOTE: Some fluorescent lights mayinterfere with the transmission of remotecontrol signals, in this case changing theposition from which you are ope

Pagina 5

131. Flue connection and proper venting2. Warm air distribution.3. Adequate air supply.4. The heater must not be installed wherecurtains or other com

Pagina 6

14• RUN GAS SUPPLYFor pipe sizing, refer to your local gasinstallation codes.• PURGE SUPPLY OF AIR ANDDEBRISAll foreign materials such as filings mus

Pagina 7 - TECHNICAL SPECIFICATIONS

15The logset is packed inside the unit andthe packaging must be removed prior toinstalling the logset in its correct position.• Open both side panels

Pagina 8

16• TESTING PROCEDURETurn gas supply on and plug the unit intothe power supply. (Caution 115V)• TO CHECK BURNER PRESSURE• Refer to rating plate.•

Pagina 9 - CONTROL PANEL LAYOUT

17IMPORTANT MAINTENANCE INSTRUCTIONSANNUAL INSPECTIONThe unit should be inspected at least oncea year by a qualified service technicianincluding insp

Pagina 10

181332113422The heater should be servicedannually only by an authorised person.• GLASS REPLACEMENT ANDCLEANING. (May be performed by theowner)It is

Pagina 11

19WIRING DIAGRAMPCB LAYOUTCaution: Label all wires prior todisconnection when servicingcontrols. Wiring errors can causeimproper and dangerousoperat

Pagina 12

2LIMITED WARRANTYRINNAI FIREPLACE HEATERWHAT IS COVERED?This Warranty covers any defects in materials or workmanship, subject to the terms stated bel

Pagina 13 - LOCATION

20NOTE:If you have any other faults or problems, please refer to your Installer or local qualified service agencyTROUBLE SHOOTINGWIRING DIAGRAM-LADDE

Pagina 14 - GAS CONNECTION

21Error code Probable cause Comments11Ignition failureCheck gas is turned on.Service call if repeated12Flame failureCheck gas is turned on.Service ca

Pagina 15 - LOG INSTALLATION

22EXPLODED DIAGRAMS

Pagina 17 - MAINTENANCE INSTRUCTIONS

24SPARE PARTS LISTITEM NO. QTY. PART NO.1 1 7992-1 FLUE SPIGOT ASSY FS NAT USA2 1 7074 HEAT EXCHANGER FRONT ASSY 3+3H3 1 7075 HEAT EXCHANGER REAR ASS

Pagina 18

2551 1 7988V REAR PANEL FS35ETR VIPER USA BLACK1 7988SP REAR PANEL FS35ETR SP USA SILVER52 1 7472 AIR GUIDE LOWER FS35ETR53 1 7062 HEATSHIELD LOWER R

Pagina 19 - WIRING DIAGRAM

26INSTALLATION NOTES

Pagina 20 - WIRING DIAGRAM-LADDER

271. Was a fireplace inspection carried out?(i.e. clearances, combustibles etc.)2. Was a manufactured flue system installed?3. Has specified gas pre

Pagina 21 - ERROR CODES

Part Number 7917zx

Pagina 22 - EXPLODED DIAGRAMS

3WARNINGIMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE ORMAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY ORLOSS OF LIFE.INSTALLATION A

Pagina 23

4Model: FS35ETRBN/US, FS35ETRSN/US (NG) United StatesFS35ETRBL/US, FS35ETRSL/US (Propane) United StatesDescription: Freestanding radiant/convector, g

Pagina 24 - SPARE PARTS LIST

58 Read these rules and the instructionscarefully. Check all local codes. Failureto follow these could cause a malfunctionof the heater resulting i

Pagina 25

6Diagram showsminimumclearances fromcombustiblematerialsof the control system and any gas controlwhich has been under water.17 Adequate clearances fo

Pagina 26 - INSTALLATION NOTES

7TECHNICAL SPECIFICATIONSCOMPARTMENTS, BURNERS ANDCIRCULATING AIR PASSAGEWAYSOF THE APPLIANCE ARE KEPTCLEAN.35 The glass window shall be replaced aso

Pagina 27 - INSTALLER DETAILS

8A This appliance is equipped with anignition device which automaticallyignites the pilot. Do not try to light thepilot by handB. BEFORE OPERATING s

Pagina 28 - Part Number 7917

9For your convenience the controls on your new Flame Fire are situated under the cover on thetop right-hand side of the fire and are accessed by simp